Silicone heater pads · 3 sizes · 3 options in stock

Silicone heater pads, square and rectangular — power density is the number that decides life. The parameters are listed in order of importance: the one at the top decides the most, and no amount of care further down makes up for getting it wrong.

This page lists 3 options: Size 100x100x2mm / 214x214x2mm / 214x214x3mm. From ¥23.

The parts of this item

The parts of a silicone heater

Figure 1 — A heater needs four numbers: size, power, voltage, lead length — the wrong voltage burns it out on power-up

What each parameter decides

Every parameter below shows the real range available on this page, and what goes wrong if you pick it wrong. Work through them in this order and you will not go far wrong.

ParameterAvailable hereWhat it decidesIf you get it wrong
Size100x100x2mm / 214x214x2mm / 214x214x3mmoverall size and the space it needsit will not fit, or it cannot be fastened down

How to choose, step by step

  1. Size and power — 100x100x2mm / 214x214x2mm / 214x214x3mm or 100x100x2mm / 214x214x2mm / 214x214x3mm plus Power. Watch the power density in W per square centimetre — above about 5 it will burn through locally.

How the options on this page are distributed

How the 3 options on this page are distributed

Figure 2 — how the 3 options on this page are spread across each parameter: the bars on the left show how many options sit in each band, the panel on the right shows the real range of every parameter and how many steps it has.

Variant quick reference

SizePart no.
100x100x2mmMK3-AL-100x100x2
214x214x2mmMK3-AL-214x214x2
214x214x3mmMK3-AL-214x214x3

Reading the part numbers

Part no.Configuration
MK3-AL-100x100x2Size 100x100x2mm
MK3-AL-214x214x2Size 214x214x2mm
MK3-AL-214x214x3Size 214x214x3mm

You can order by part number or by selecting the parameters. The part number is fastest, but it does not always encode every parameter — the selector on this page is the authority.

8 common mistakes

  1. Wrong voltage burns through. A 24 V pad on 220 V is destroyed in seconds; a 220 V pad on 24 V simply never gets warm.
  2. Power density is what kills pads. The same wattage over a smaller area runs much hotter and fails much sooner. Stay at 2–5 W per square centimetre.
  3. It has to be in contact. An air gap or a bubble under the pad creates a hot spot and the pad burns through right there.
  4. It needs a controller. A silicone pad has no self-limiting — uncontrolled it climbs until something fails.
  5. 220 V must be earthed. This is a safety requirement, not a recommendation.
  6. Do not fold or crease a pad. The element wire inside breaks at the crease and the whole pad is dead.
  7. Measure before you order. Take the old part off and measure it, or send us a photo with the caliper reading — that beats guessing from a model number every time.
  8. Everything here is in millimetres. Where a size is imperial, convert it: 1" = 25.4 mm, 1/4" = 6.35 mm, 3/32" = 2.38 mm.

When to replace it

You do not replace this until it fails — but "still looks usable" and "still reliable" are two different things. Any one of these and it is time:

  • Surface bulging or a blackened patch — the element is about to burn through. Stop using it now.
  • Resistance more than 10% off the rating.
  • Backing failed and it is lifting, which causes local overheating.

Fitting and use

Before wiring

  • Confirm voltage and polarity first. Reversed, it is destroyed on the first switch-on — there is no second chance. DC parts especially.
  • Wire with the power off, then check continuity and insulation with a meter before you apply power.
  • Crimp or tin the wire ends. Twisting bare strands onto a terminal gives a high-resistance joint that heats up.

Mounting

  • Leave the heated parts some air. Do not mount them against plastic or against the cable run.
  • Parts with a direction (fans, check valves) have an arrow. Reversed, you lose most of the airflow or flow.
  • Fasten it properly. Vibration loosens terminals, and loose terminals are the most common electrical failure there is.

First power-up

  • First power-up from a current-limited supply, or through a fuse. If something is wrong the damage stays small.
  • Run it unloaded first, measure current and temperature, then add load.
  • After 30 minutes feel the terminals and the cable. Anything noticeably warm means high contact resistance — re-crimp it.

Three things not to do

  • Do not connect or disconnect under power unless it is explicitly rated for hot-plug. The arc damages the terminals.
  • Do not run above the rating. It works for a while, then it does not.
  • Do not skip the earth or the fuse. You save a few yuan and risk the machine.

Matching parts

  • Controller and thermistor
  • Thermal adhesive or backing
  • Insulation blanket

Lead time, custom work and shipping

  • Stock sizes: dispatched in 1–2 working days, subject to stock
  • Custom: non-standard sizes, materials and treatments are possible — send quantity and drawing
  • Shipping: from Shenzhen; domestic courier by default, DHL or dedicated line for export
  • Volume: quantity pricing available, contact us for a quote

If you cannot find the size you need, or you are not sure which one fits, send us the problem you are solving — what machine it goes on, the dimensions of the part you have, what it has to achieve — and we will match it.

Home Products OEM & Custom About Us Contact Us Catalog +86 (0755) 23221210