YD20 Waterproof Aviation Connector (spindle motor)
Aviation connectors · 30 styles · 30 options in stock
Aviation connectors — GX series plugs and sockets, sized by thread and core count. The parameters are listed in order of importance: the one at the top decides the most, and no amount of care further down makes up for getting it wrong.
This page lists 30 options: Style / variant Formal YD20-3 core socket / Formal YD20-3-core plug / Formal YD20-4 core socket / Formal YD20-4-core plug … 30 total. From ¥7.15.
The parts of this item
Figure 1 — Cable needs three things: cores, gauge, length — connectors are extra; leave them out and you crimp your own
What each parameter decides
Every parameter below shows the real range available on this page, and what goes wrong if you pick it wrong. Work through them in this order and you will not go far wrong.
| Parameter | Available here | What it decides | If you get it wrong |
|---|---|---|---|
| Style / variant | Formal YD20-3 core socket / Formal YD20-3-core plug / Formal YD20-4 core socket / Formal YD20-4-core plug … 30 total | the structural and shape differences | it will not fit, or it will not do the job your mechanism needs |
How to choose, step by step
- Plug or socket — Formal YD20-3 core socket / Formal YD20-3-core plug / Formal YD20-4 core socket / Formal YD20-4-core plug … 30 total. A plug needs its matching socket.
How the options on this page are distributed
Figure 2 — how the 30 options on this page are spread across each parameter: the bars on the left show how many options sit in each band, the panel on the right shows the real range of every parameter and how many steps it has.
Variant quick reference
| Style / variant | Part no. |
|---|---|
| Reverse installation YD20-3-pin plug | EG-007-FZ-YD20-3X-CT |
| Reverse installation YD20-3 core socket | EG-007-FZ-YD20-3X-CZ |
| Reverse installation YD20-4-pin plug | EG-007-FZ-YD20-4X-CT |
| Reverse installation YD20-4 core socket | EG-007-FZ-YD20-4X-CZ |
| Reverse installation YD20-5-pin plug | EG-007-FZ-YD20-5X-CT |
| Reverse installation YD20-5 core socket | EG-007-FZ-YD20-5X-CZ |
| Reverse installation YD20-7-pin plug | EG-007-FZ-YD20-7X-CT |
| Reverse installation YD20-7 core socket | EG-007-FZ-YD20-7X-CZ |
| Reverse installation YD20J3TP 3-pin plug + socket | EG-007-FZ-YD20J3TP-3X-CT-CZ |
| Reverse installation YD20J4TP 4-pin plug + socket | EG-007-FZ-YD20J4TP-4X-CT-CZ |
| Reverse installation YD20J5TP 5-pin plug + socket | EG-007-FZ-YD20J5TP-5X-CT-CZ |
| Reverse installation YD20J7TP 7-pin plug + socket | EG-007-FZ-YD20J7TP-7X-CT-CZ |
| Reverse installation YD32-19 core plug | EG-007-FZ-YD32-19X-CT |
| Reverse installation YD32-19 core socket | EG-007-FZ-YD32-19X-CZ |
| Reverse installation YD32J19TP 19-pin plug + socket | EG-007-FZ-YD32J19TP-19X-CT-CZ |
| Formal YD20-3-core plug | EG-007-ZZ-YD20-3X-CT |
| Formal YD20-3 core socket | EG-007-ZZ-YD20-3X-CZ |
| Formal YD20-4-core plug | EG-007-ZZ-YD20-4X-CT |
| Formal YD20-4 core socket | EG-007-ZZ-YD20-4X-CZ |
| Formal YD20-5-pin plug | EG-007-ZZ-YD20-5X-CT |
| Formal YD20-5 core socket | EG-007-ZZ-YD20-5X-CZ |
| Formal YD20-7-pin plug | EG-007-ZZ-YD20-7X-CT |
| Formal YD20-7-pin socket | EG-007-ZZ-YD20-7X-CZ |
| Formal YD20K3TP 3-pin plug + socket | EG-007-ZZ-YD20K3TP-3X-CT-CZ |
| Formal YD20K4TP 4-pin plug + socket | EG-007-ZZ-YD20K4TP-4X-CT-CZ |
| Formal YD20K5TP 5-pin plug + socket | EG-007-ZZ-YD20K5TP-5X-CT-CZ |
| Formal YD20K7TP 7-pin plug + socket | EG-007-ZZ-YD20K7TP-7X-CT-CZ |
| Formal YD32-19 core plug | EG-007-ZZ-YD32-19X-CT |
| Formal YD32-19 core socket | EG-007-ZZ-YD32-19X-CZ |
| Formal YD32K19TP 19-pin plug + socket | EG-007-ZZ-YD32K19TP-19X-CT-CZ |
Reading the part numbers
| Part no. | Configuration |
|---|---|
EG-007-FZ-YD20-3X-CT | Style / variant Reverse installation YD20-3-pin plug |
EG-007-FZ-YD20-3X-CZ | Style / variant Reverse installation YD20-3 core socket |
EG-007-FZ-YD20-4X-CT | Style / variant Reverse installation YD20-4-pin plug |
You can order by part number or by selecting the parameters. The part number is fastest, but it does not always encode every parameter — the selector on this page is the authority.
6 common mistakes
- Plug and socket come in pairs. Two plugs do not connect, however similar the shells look.
- The number after GX is the thread diameter. GX12 and GX16 do not mate and there is no adapter.
- Solder joints have to be sound. A cold joint gives an intermittent fault that you will chase for a week.
- Check the pin arrangement. The same shell can be wired with different pin counts and keyways.
- Measure before you order. Take the old part off and measure it, or send us a photo with the caliper reading — that beats guessing from a model number every time.
- Everything here is in millimetres. Where a size is imperial, convert it: 1" = 25.4 mm, 1/4" = 6.35 mm, 3/32" = 2.38 mm.
When to replace it
You do not replace this until it fails — but "still looks usable" and "still reliable" are two different things. Any one of these and it is time:
- Pins blackened and oxidised; intermittent contact.
- Shell thread stripped and it will not lock.
Fitting and use
Before wiring
- Confirm voltage and polarity first. Reversed, it is destroyed on the first switch-on — there is no second chance. DC parts especially.
- Wire with the power off, then check continuity and insulation with a meter before you apply power.
- Crimp or tin the wire ends. Twisting bare strands onto a terminal gives a high-resistance joint that heats up.
Mounting
- Leave the heated parts some air. Do not mount them against plastic or against the cable run.
- Parts with a direction (fans, check valves) have an arrow. Reversed, you lose most of the airflow or flow.
- Fasten it properly. Vibration loosens terminals, and loose terminals are the most common electrical failure there is.
First power-up
- First power-up from a current-limited supply, or through a fuse. If something is wrong the damage stays small.
- Run it unloaded first, measure current and temperature, then add load.
- After 30 minutes feel the terminals and the cable. Anything noticeably warm means high contact resistance — re-crimp it.
Three things not to do
- Do not connect or disconnect under power unless it is explicitly rated for hot-plug. The arc damages the terminals.
- Do not run above the rating. It works for a while, then it does not.
- Do not skip the earth or the fuse. You save a few yuan and risk the machine.
Matching parts
- Cable and heat shrink
Lead time, custom work and shipping
- Stock sizes: dispatched in 1–2 working days, subject to stock
- Custom: non-standard sizes, materials and treatments are possible — send quantity and drawing
- Shipping: from Shenzhen; domestic courier by default, DHL or dedicated line for export
- Volume: quantity pricing available, contact us for a quote
If you cannot find the size you need, or you are not sure which one fits, send us the problem you are solving — what machine it goes on, the dimensions of the part you have, what it has to achieve — and we will match it.